Strany 1 - Novus FXM 650 / 1100 /2000

Alpha Technologieswww.alpha.comOperator’s Manual017-201-B0 Rev 05/07Novus FXM 650 / 1100 /2000Uninterruptible Power Supply

Strany 2 - Alpha Technologies

1 Battery BreakerThis circuit breaker provides overcurrent protection and is an on/off switch for battery power. It must be on for proper UPS operatio

Strany 3 - Operator’s Manual

5 LCD Control PanelThis panel and the cancel, scroll and select buttons below it let you monitor and control the UPS. More information is given in Sec

Strany 4 - Table of Contents

9 Contacts C1 to C6Contacts C1 to C5 allow you to connect the UPS to an external monitoring panel or to trafc control equipment.The factory default s

Strany 5

10 Contacts C7 and C8These optically isolated inputs let you attach an external switch panel for remote control of the UPS or have the UPS control Alp

Strany 6

12 Input Circuit BreakerThis circuit breaker is an on/off switch for line power into the UPS and provides input protection. It must be on for proper U

Strany 7

11InstallationThis Section Tells You How to Install and Wire the Novus FXM UPSSite Preparation Checklist (Section 2.1)• Mounting the UPS (Section 2.2)

Strany 8

2.1 Site Preparation Checklist F Grounding The UPS MUST be correctly grounded for proper operation. Older facilities may have inadequate electrical g

Strany 9 - Novus FXM 650 Front Panel

2.2 Mounting the UPSThe UPS can be placed on a shelf with no other parts needed. Any version of the FXM can be rack or wall mounted or secured to a sh

Strany 10 - Doc# 017-201-B0 Rev 05/07

2.3 Wiring the External Batteries DANGER: Before starting, make sure you have read the instructions on battery safety in Section 1.1 of this manual.To

Strany 11 - Introduction

Procedure1. For FXM 1100/2000 and FXM 650-48 (48 V battery string), number the batteries from 1 to 4 with labels or tape as shown in Figure 2.3.1a. F

Strany 12 - Microprocessor

PowerAlpha Technologies®

Strany 13

DANGER: Before starting, make sure line power is turned off and that the UPS’s battery and input circuit breakers are turned off. If stranded wires a

Strany 14

DANGER: Before proceeding, verify the line wire is attached to the line terminal block, the ground wire is attached to the ground terminal block and

Strany 15 - Installation

18OperationThis Section Tells You How to Operate the Novus FXMOperating the Control Panel (Section 3.1)• Turning the UPS On and Off (Section 3.2) • Re

Strany 16

3.1 Operating the Control PanelThe LCD control panel provides “at a glance” monitoring. This panel, when used along with the CANCEL, SCROLL and SELECT

Strany 17

Pressing the CANCEL, SCROLL and SELECT buttons let you to navigate through the menus and submenus to control, monitor and troubleshoot the UPS as show

Strany 18

3.2 Turning the UPS On and OffIf the UPS constantly switches between Inverter and Line modes due to a noisy line, the UPS’s input parameters should be

Strany 19

3. Turn off the input circuit breaker.The LCD shows INVERTER, the status LED starts ashing to show the UPS is running on backup battery power. Make

Strany 20

3.3 Replacing the BatteriesDuring battery replacement the UPS cannot provide backup battery power. This procedure should NOT be done when critical loa

Strany 21 - Battery connector

The control menu (Figure 3.4.1) lets you operate the UPS or program it to suit your operating conditions. You can also use the Novus User Software to

Strany 22 - Operation

Control Menu (Continued)BATT TEST Battery Test This is the UPS’s self test. When it is turned on, the UPS is forced to verify its proper operation by

Strany 23 - 120/60/N

Uninterruptible Power SuppliesAlpha Technologies www.alpha.com017-201-B0 Rev. 02 / 07Operator’s ManualNovus FXM 650 / 1100 / 2000FXM 650FXM 1100/2000

Strany 24 -  Starting at the Logo

3.5 Making MeasurementsThe system status menu (Figure 3.5.1) lets you make measurements of various UPS inputs, outputs, temperatures and other values.

Strany 25

System Status MenuDATE Date The date and time (24 hour clock).TIME TimeINV COUNT Inverter Count The number of times the UPS was in inverter mode.INV T

Strany 26

3.6 Troubleshooting the UPSWhen the front panel alarm LED is on or ashing, the UPS has a malfunction. The alarm and fault submenus (Figure 3.6.1) des

Strany 27 - Control Panel Tutorial

Fault SubmenuLCD Shows DescriptionOverload Fault The load draws more power than the UPS can provide. This can lead to an automatic UPS shutdown. Remov

Strany 28 - Control Menu

3.7 Viewing the 25-Event LogThe event menu displays on the LCD the last 25 events the UPS went through and the malfunction that triggered it. If more

Strany 29 - Control Menu (Continued)

31CommunicationThis Section Tells You How To Operate the Novus FXM With RS-232 Computer Commands How to Wire the RS-232 Port (Section 4.1)• How to Use

Strany 30 - System Status Menu

4.1 Wiring the RS-232 PortThe UPS’s front panel has a DB-9 female connector. When connected to a PC with Window’s HyperTerminal or other terminal emul

Strany 31

4.2 Using the Main MenuThe UPS’s main menu screen runs on a command line system (Figure 4.2.1). This program does not recognize the backspace or delet

Strany 32 - ALARM STATUS

4.2.2 RS-232 Menu TreeSubmenus #1, 2 and 4 are read-only screens for monitoring the UPS. To control the UPS, use submenu #3, the Maintenance submenu.1

Strany 33 - Fault Submenu

4.2.3 Line StatusLine status tells you the line’s condition (Also see Figure 3.1.2). For an updated value, press ENTER.4.2.4 Output StatusOutput statu

Strany 34 - Over Load

Save This Manual: It contains important installation and operating instructions. Keep it in a safe place.Table of ContentsThe emergency shutdown proce

Strany 35 - Communication

4.2.5 Fault and Alarm DisplaysThese display any malfunctions the UPS has (Also see Section 3.6).Line Status: NormalOutput Status: Line ModeFaults: Sho

Strany 36 - Parameters

4.3 Adjusting and Controlling the UPSThe Maintenance submenu (Figure 4.3.1) lets you control the UPS and change selected items to meet your operationa

Strany 37

4.4 Programming the Dry Contacts and the ClockThe UPS’s front panel contacts (Section 1.3.1, “FXM 1100/2000, Contacts C1 to C6”) can be programmed to

Strany 38 - 4.2.2 RS-232 Menu Tree

4.4.2 Setting the Timer Contact The front panel’s timer contact (Section 1.3.1, “FXM 1100/2000, Contacts C1 to C6” and Section 4.4.1) can be programme

Strany 39

Up to 100 events are stored in the UPS’s log. If more than 100 events occur, the oldest is over written.Procedure1. To see the log, type event (all l

Strany 40

4.6 Novus User Software4.6.1 IntroductionThe Novus User Software Graphical User Interface (GUI) provides Web or Windows© like computer communications

Strany 41 - Maintenance Submenu

If you are downloading from Microsoft’s web site, you must have Internet Explorer installed on your computer. In addition to installing .NET, download

Strany 42

3. Set the communications parameters on your computer to:• COM Port: The COM port on your computer you have selected to use.• Baud Rate: 2400.4. T

Strany 43

UPS SPECIFICATIONThis read-only screen shows the UPS’s factory-set specications.UPS MONITORINGThese read-only screens show the UPS’s current input an

Strany 44 - Code Mode Code Mode Code Mode

ALARMS & FAULTS This read-only screen shows you what malfunctions the UPS has (Also See Section 3.6, “Troubleshooting”). When the fault or alarm i

Strany 45 - Figure 4.6.1

1IntroductionThis Section Introduces the Novus FXM Uninterruptible Power Supply (UPS)Safety Instructions (Section 1.1)• Unpacking and Inspection Instr

Strany 46 - Add or Remove Programs Window

46MaintenanceThis Section Tells You How To Maintain the Novus FXM How to Replace the Software (Section 5.1)• 5

Strany 47

5.1 Updating the SoftwareThe UPS’s rmware can be reinstalled or updated to the latest version with this procedure.Tools and Materials Required• RS-2

Strany 48

6. Type (all lower case) oad(1 space);b and press ENTER. A pop-up appears asking you to locate the new rmware. Look for a “sx record” (*.sx). Selec

Strany 49

MechanicalSpecicationsDimensions, in (mm) H x W x D1100-2000: 5.22 x 15.5 x 8.75(133 x 394 x 222)650: 3.47 x 17 x 9(89 x 432 x 229)Weight, lb (kg)

Strany 50 - Maintenance

Boost/Buck/Line Transfer ThresholdsSubject to change without noticeParameter 120VAC Units230VAC UnitsFXM 2000 (120VAC)High Line TransferHigh Line Retr

Strany 51 - V0.0.0.1

Note: Listings in BOLD ALL UPPER CASE are entries as displayed on the LCD panelSymbols100-Event Log ...4025-Event Log ...

Strany 52

Note: Listings in BOLD ALL UPPER CASE are entries as displayed on the LCD panelRRS-232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 53 - ElectricalSpecications

53IndexDoc# 017-201-B0 Rev 05/07This page is left blank intentionally.

Strany 54 - • CSA

54WarrantyLIMITED 24-MONTH WARRANTYAC PRODUCTSAlpha Technologies warrants its equipment to be free of manufacturing defects in material and workmanshi

Strany 55

Emergency Shutdown ProcedureThe Novus FXM has more than one live circuit. In an emergency, line power may be disconnected at the input, but there can

Strany 56

1.1.1 UPS Safety ChecklistThis Uninterruptible Power Supply (UPS) must be installed in a restricted access location, and by trained personnel qualied

Strany 57

PowerAlpha Technologies®Due to continuing product improvements, Alpha reserves the right to change specications without notice. Copyright © 2007 Alph

Strany 58 - Warranty

1.1.2 Battery Safety Checklist Battery Emergency Procedures If electrolyte splashes on your skin, immediately wash the affected area with water. If e

Strany 59 - Emergency Shutdown Procedure

If items are missing or damaged, contact Alpha Technologies and the shipping company at once. Most shippers have a short claim period.Carefully remove

Strany 60

1.3 The FXM Front PanelThe FXM UPS is available in 3 models – FXM 650, FXM 1100 and FXM 2000. The FXM 650 and the FXM 1100/2000 look different, but al

Komentáře k této Příručce