CFR
7.5K, 10K, 15K
Uninterruptible Power Supplies
From Alpha Technologies
!!
!!
! Operators Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 86 87

Shrnutí obsahu

Strany 1 - 7.5K, 10K, 15K

CFR7.5K, 10K, 15KUninterruptible Power SuppliesFrom Alpha Technologies!!!!! Operator’s Manual

Strany 2 - Operator’s Manual

1 Introduction41.2 The Alpha CFR 7.5K, 10K and 15K (Continued)1.2.1 Front PanelDisplay PanelThis is either the Standard Interface Display(SID) (Sectio

Strany 3 - Save This Manual

5 1 Introduction1.2 The Alpha CFR 7.5K, 10K and 15K (Continued)1.2.2 Rear PanelFansThese four fans cool the unit. They must not be blocked.Output Term

Strany 4 - Safety Checklists

1 Introduction61.2 The Alpha CFR 7.5K, 10K and 15K (Continued)Battery Circuit BreakerThis protects the unit’s inverter and DC circuits andcan be used

Strany 5 - Safety Checklists (Continued)

7 1 Introduction1.2 The Alpha CFR 7.5K, 10K and 15K (Continued)External Alarm ConnectorThis RJ–45 connector allows the connection of anexternal alarm

Strany 6 - Table of Contents

8Section 2InstallationThis section shows you how to unpack,install and connect the Alpha 7.5K, 10Kand 15K CFR UPS’s:• A pre-installation checklist (S

Strany 7 - Section 1

9 2 Installation2.1 Pre–Installation Checklist2.1.1 Site PreparationInstall the unit upright in a dry, well-ventilated, dust free environment. There m

Strany 8 - 1.1 The CFR Advantage

2 Installation10The unit should be wired to dedicated circuit equipped with a properly sized circuit breaker.The breaker’s size is the unit’s maximum

Strany 9 - Read This Manual

11 2 Installation2.2 Unpacking and TransportationTIP: If items are missing or damaged, contact Alpha and the shipping company atonce. Most shippers ha

Strany 10

2 Installation122.2 Unpacking and Transportation (Continued)4Remove the plastic wrap from around the unit.2Remove the corner support pieces by lifting

Strany 11 - Output Receptacles

13 2 Installation2.2 Unpacking and Transportation (Continued)WARNING: Do not use a pallet jack or similardevice for moving the unit since only one bla

Strany 12

!!!!!Operator’s Manual!!!!!CFR 7.5K, 10K, 15KUninterruptible Power Supplies

Strany 13 - External IID

2 Installation142.2 Unpacking and Transportation (Continued)8Lift the unit off of the pallet. Remove the wood /foam shock absorber. Transport it to th

Strany 14 - Section 2

15 2 Installation2.3 Connecting the Internal BatteriesFor safety reasons the 7.5K and 10K unit’s internal batteries have been disconnected at thefacto

Strany 15 - 2.1.1 Site Preparation

2 Installation162.3 Connecting the Internal Batteries (Continued)Opening Finished. Go to Step 2.Perform 6 to 2 in reverse order to replace the panels

Strany 16 - 2.1.4 Installation Sequence

17 2 Installation2.3 Connecting the Internal Batteries (Continued)Step 2: Connect the BatteriesDANGER: There is up to 165 VDC inside the unit when the

Strany 17 - 16 inch socket wrench

2 Installation182.4 Mounting the Seismic BracketsTIP: The seismic brackets can be removed if they are not required by local code or youare not in an e

Strany 18

19 2 Installation2.4 Mounting the Seismic Brackets (Continued)0.781 inch diameter for mounting 0.75 inch (19 mm) anchor bolts(such as Hilti #665927 (H

Strany 19 - 16 inch socket wrench, remove

2 Installation202.6 Connecting the Terminal BlocksWARNINGS:1) Wiring should meet all local electrical codes and be done only by qualified personnel.2)

Strany 20

21 2 Installation2.6 Connecting the Terminal Blocks (Continued)4Replace the cover plate.5To wire the output terminal block, repeat 2 to 4, except wire

Strany 21 - Procedure:

2 Installation222.7 Connecting the External Battery Packs (Continued)Procedure:1Verify the battery circuit breaker is off. Keep it offuntil after the

Strany 22

23 2 Installation2.7 Connecting the External Battery Packs (Continued)Disconnecting the EBPThe EBP connector has a lock to firmly attach it to the uni

Strany 23

CFR 7.5K, 10K, 15KNOTICE:The CFR 7.5K, 10K and 15 K generates, uses and can radiate radio frequencies if not installed andtested in accordance with th

Strany 24

2 Installation242.8 Connecting the External Alarm PortAn external alarm panel can be connected to the external alarm port (Figure 2.4). The port’scont

Strany 25 - 2.5 Locking the Wheels

25 2 Installation2.9 Connecting the RS–232 PortThe unit can be remotely setup, monitored, and tested by connecting the unit’s DB–9 connectorto a compu

Strany 26

2 Installation262.10 Transformer Output Load Sharing2.10.1: Transformer OutputThe units have a single phase output. It does NOT have three phase chara

Strany 27

27 2 Installation2.10 Transformer Output Load Sharing (Continued)2.10.2.1: Measuring the Output CurrentThis uses a clip-on current probe (Figure 2.8 f

Strany 28 - EBP 144 Series Battery Packs

2 Installation282.10 Transformer Output Load Sharing (Continued)2.10.2.2: Displaying the Output CurrentTIP: When using the display panels, you must ca

Strany 29 - Figure 2.3

29Section 3OperationThis section shows you how to operatethe Alpha 7.5K, 10K and 15K CFR UPS’s:• How to turn the unit on and off (Sections 3.1, 3.2).•

Strany 30 - 87654321

3 Operation303.1 Turning On the UnitWARNINGS:1) This unit runs warm to the touch. During the first few weeks of operation, a brand newunit may give of

Strany 31 - TXDRXDGND

31 3 Operation3.1 Turning On the Unit (Continued)Cold Start ProcedureThis starts the unit with battery power when line power is unavailable or unquali

Strany 32 - 2.10.2: Load Sharing

3 Operation323.3 Testing the UnitThe self test confirms the unit can switch from line power to backup battery power and backwithout interrupting power

Strany 33

33 3 Operation3.4 Troubleshooting With the SIDThe SID’s Output Load LEDs have two functions:• When the unit is operating normally, it serves to show t

Strany 34 - Terminal Block

CFR 7.5K, 10K, 15KSafety ChecklistsDANGER: Sealed lead-acid batteries with high energy and chemical hazards areused. This manual contains important op

Strany 35 - Section 3

3 Operation343.5 Controlling the Unit With the Standard Interface Device (SID)The Standard Interface Device (SID) display panel (Figure 3.2) shows vit

Strany 36 - 3.1 Turning On the Unit

35 3 OperationLow Battery ShutdownThis red LED turns on when the battery voltage is 12% below nominal. The unit automati-cally shuts itself down and n

Strany 37 - 3.2 Turning Off the Unit

3 Operation363.5 Controlling the Unit With the Standard Interface Device (SID) (Continued)Output LoadThese five green LED's show the unit’s loadi

Strany 38 - 3.3 Testing the Unit

37Section 4CommunicationThis section shows you how to controlthe Alpha 7.5K, 10K and 15K CFR UPS’swith RS–232 computer commands:• How to set-up commun

Strany 39 - Troubleshooting Finished

4 Communication384.1 Setting Up RS–232 CommunicationsWire the DB–9 connector as shown in Section 2.9, “Connecting the RS–232 Port.”Windows HyperTermin

Strany 40 - Low Battery Warning

39 4 Communication4.1 Setting Up RS–232 Communications (Continued)4The Com 1 Properties screen appears(Figure 4.3). Fill out the fields as shown.5Clic

Strany 41

4 Communication404.2 Using the Opening MenuThe opening menu (Figure 4.5, also see Figure 4.4) is the top-level menu. It shows the line’sstatus, displa

Strany 42 - Output Load

41 4 Communication4.2 Using the Opening Menu (Continued)Figures 4.6 to 4.9 list the alarms, how they appear on the screen and what they mean.Figure 4.

Strany 43 - Section 4

4 Communication424.2 Using the Opening Menu (Continued)Figure 4.9Environmental and Service AlarmssmralAecivreSdnalatnemnorivnEsmralAecivreSdnalatnemno

Strany 44 - Procedure

43 4 Communication4.3 Menu Tree• To reach any main or sub menu from the opening menu, type its number and press Enter.• Detailed descriptions of each

Strany 45 - Finished

CFR 7.5K, 10K, 15KiiiSafety Checklists (Continued)There are dangerous voltages inside the unit. Only qualified personnel should performinstallation an

Strany 46 - 4.2 Using the Opening Menu

4 Communication444.4 System, Input, Output & Battery ParametersMain menus #1 to #4 are read only menus which display important operating paramete

Strany 47

45 4 Communication4.4 System, Input, Output & Battery Parameters (Continued)4.4.3 Main Menu #3: Output ParametersThis displays selected output pa

Strany 48

4 Communication464.4 System, Input, Output & Battery Parameters (Continued)Output Terminal BlockLNOutput Voltage 1230 VAC ReceptacleOutput Curren

Strany 49 - 4.3 Menu Tree

47 4 Communication4.5 User ParametersMain menu #5, user parameters, lets you set up the automatic self test, remotely shut down theunit, change the p

Strany 50

4 Communication484.5 User Parameters (Continued)4.5.2 Sub Menu #50: Set Output Shutdown ParametersThese menus allow you to turn the unit’s output on

Strany 51

49 4 Communication4.5 User Parameters (Continued))deunitnoC(sretemaraPnwodtuhStuptuOteS)deunitnoC(sretemaraPnwodtuhStuptuOteS)deunitnoC(sretemaraPnwo

Strany 52 - Output Voltage 1

4 Communication504.5 User Parameters (Continued)4.5.3 Sub Menu #56: Transmit Unsolicited AlarmsThese menus allow you to prevent or delay the continuo

Strany 53 - 4.5 User Parameters

51 4 Communication4.6 Maintenance ParametersMain menu #7, maintenance parameters, allows you to adjust the unit’s detection and warningparameters to

Strany 54 - )deunitnoC(sretemaraPresU

4 Communication524.7 Installing and Using the External ModemUses of the External ModemWhere a network is not available, you can connect an external m

Strany 55 - Figure 4.16

53 4 CommunicationStep 1: Enable the CFR’s Modem FeatureThe CFR is shipped with the modem feature disabled. To enable it:1 Connect a computer to the C

Strany 56

CFR 7.5K, 10K, 15KivTable of ContentsThe emergency shutdown procedure is on the inside rear cover1. Introduction ...

Strany 57 - 4.6 Maintenance Parameters

4 Communication544.7 Installing and Using the External Modem (Continued)Step 2: Connect and Configure the ModemUse a shielded, null-modem serial cabl

Strany 58 - Settings:

55 4 Communication3 The initialization string (Item #527) is a set of commands the CFR sends to themodem to initialize it. For a US Robotics modem, th

Strany 59

4 Communication56Step 3: Initalize the ModemTo initalize the modem start a CFR self test (Section 3.3).The CFR must initialize the modem. If a remote

Strany 60

57 4 Communication4.7 Installing and Using the External Modem (Continued)How the CFR Sends AlarmsTo send an alarm, the CFR sends the dial command to

Strany 61

4 Communication584.7 Installing and Using the External Modem (Continued)Figure 4.22External Modem Setup MenusuneMputeSmedoMlanretxEsuneMputeSmedoMlan

Strany 62 - Modem Installation Finished

59 4 Communication4.7 Installing and Using the External Modem (Continued))deunitnoC(suneMputeSuneMmedoMlanretxE)deunitnoC(suneMputeSuneMmedoMlanretxE

Strany 63 - How the CFR Sends Alarms

60Section 5MaintenanceThis section describes how to maintainthe Alpha 7.5K, 10K and 15K CFR UPS’s:• How to measure the battery backup time (Section5.1

Strany 64

615 Maintenance5.1 Testing the Battery Backup TimeThis test measures how long the batteries can provide backup power by having them power theloads unt

Strany 65

5 Maintenance625.2 TroubleshootingMost problems involve:• Are the Input, Battery and Output circuit breakers switched on?• Is the input voltage correc

Strany 66 - Section 5

635 Maintenance5.2 Troubleshooting (Continued)Figure 5.1Troubleshooting Table (Continued)motpmySmotpmySmotpmySmotpmySmotpmyS esuaCesuaCesuaCesuaCesuaC

Strany 67

1Section 1IntroductionThis section introduces you to the Alpha7.5K, 10K and 15K CFR UPS’s:• The CFR advantage (Section 1.1).• An tour of the unit, it’

Strany 68 - 5.2 Troubleshooting

5 Maintenance645.3 Returning the CFR to Alpha for RepairsIf you need to return a unit for repair, obtain a Return Material Authorization (RMA) number

Strany 69

655 MaintenanceStep 1: Remove the Front Panel and Left Side CoverRemove the front, left side and top panels as described in Section 2.3, “Connecting t

Strany 70 - 8 inch wrenches

5 Maintenance665.4 Replacing the Internal Batteries (Continued)Step 3: Replace the BatteriesProcedure:1 Switch off the battery, input and outputcircui

Strany 71 - 162 VDC and 168 VDC

675 Maintenance5.4 Replacing the Internal Batteries (Continued)7 Replace the batteries.8 Replace the battery retention bar.9 One tray at a time, wir

Strany 72 - 4 inch hex screws) and then

5 Maintenance685.5 Configuring the Input/Output VoltageThe input and output voltages are factory configured to your specifications. You can changethem

Strany 73 - Unit Front

695 Maintenance7 Replace the unit’s cover. Turn the unit on (Section 3.1).TIP: You may want to measure the output voltage to make sure this procedure

Strany 74 - AC INPUT

5 Maintenance70The times in these charts are to be used in conjunction with the battery run time you measured inSection 5.1, “Testing the Battery Back

Strany 75

715 Maintenance5.6 Battery Run Times (Continued)K01RFCK01RFCK01RFCK01RFCK01RFCsetuniM:sruoHnisemitllAdaoL%daoL%daoL%daoL%daoL%)W(tuptuO)W(tuptuO)W(tup

Strany 76 - K5.7RFCK5.7RFC

5 Maintenance725.7 SpecificationsnoitcetorPtiucriCnoitcetorPtiucriCnoitcetorPtiucriCnoitcetorPtiucriCnoitcetorPtiucriCK5.7K5.7K5.7K5.7K5.7 K01K01K01K0

Strany 77 - 5 Maintenance

735 Maintenance5.7 Specifications (Continued)SNOITACIFICEPSSPURFCSNOITACIFICEPSSPURFCSNOITACIFICEPSSPURFCSNOITACIFICEPSSPURFCSNOITACIFICEPSSPURFCK5.7K

Strany 78 - 5.7 Specifications

1 Introduction21.1 The CFR Advantage! Advanced Power Protection TechnologyAlpha’s CFR Uninterruptible Power Supply (UPS) provides continuous and condi

Strany 79

74IndexAAdjusting Unit to Local Line Conditions ... 51Alpha, Returning Unit to for Repair ... 64Alarm Off Button on SID

Strany 80

75IndexPre–Installation... 9–10Common Problems ...62–63ComputerAl

Strany 81

76IndexInspection Checklist ... See Unpacking ChecklistInstallationInstallation Checklist ...ii, 11Installat

Strany 82

77IndexRRear Panel ... 5–7Reconfiguring Input/Output Voltage ...68–69Remote Moni

Strany 83

78IndexUUnit Shutdown via External Power Off Switch ... 24Unpacking Checklist ... 11Utility LineAcceptabl

Strany 84

79WarrantyAlpha Technologies warrants its equipment to be free of manufacturing defects in material and workmanshipfor a period of 24 months from the

Strany 85 - LIMITED 24-MONTH WARRANTY

For emergency technical support 7 days a week / 24 hours a day call:USA: 1–800–863–3364CANADA: 1–800–667–8743For technical information, contact Alpha

Strany 86 - (mounted on wall)

Alpha sales and service offices located throughout the world© 2003 Alpha Technologies http://www.alpha.comPrinted In Canada 017–081–B0 07 /

Strany 87

3 1 Introduction1.2 The Alpha CFR 7.5K, 10K and 15KComplete the following for your recordsSerial # __________________________________Options _________