Alpha 1000 Handbook
Part Number 17027
Input Parameters
Adjustment and Derating.
The Alpha 1000 series is designed to provide a max output power of 1000W at nominal output
voltages. The following procedure must be used to ensure the PSU is operated within its ratings:
a Calculate the user for power for each module (Volts x Amps).
b Total power for slots 1-3 must be
720W. Total power for slots 4-7 must be 600W.
Total power (slots 1-7) not exceeding value stipulated in unit limitations table
c Calculate user ampere turns (Amps x turns) for each module.
d Add total ampere turns: Slots 1-3
120. Slots 4-7 120. Total of slots 1-7 200AT.
NOMINAL INPUT VOLTAGE RANGE 94.4 - 240VAC or 133VDC-328VDC
MAX. INPUT VOLTAGE RANGE 85-264VAC or 120-360VDC
INPUT FREQUENCY 47-63Hz
MAXIMUM INPUT CURRENT 16 AMPS or 11 AMPS DC
INRUSH CURRENT <50 AMPS
Module Limitations
1 For B, BB, Q, L and Z modules in slot 7, max output current is 15A.
2 For D and E modules in slot 7, max output current is 5A
3 For G modules in slot 6 & 7, max output current is 15A.
4 For C, CH, CL, CM modules in slot 7, max output current is 10A.
5 For S modules in slots 5 and 6 max output current is 77A and in slots 6 and 7 max
output current is 67A.
6 For C and CH modules the max output current is 12A for output voltages > 12V.
7 For J modules the output current derates linearly by 0.25A per volt above 40V.
8 For H and N modules with output > 29V, max output current is 1A .
9 When using remote sense, the max output voltage will be reduced by 0.5V for L, S, T,
Q and R modules, and by 1.0V for C, CH, CL, CM, D, F, G, J, M, K, N, U Modules.
10 Ampere turns for J module is calculated as AT=(output current + 15A) x 4.
11 Adjusting output voltage beyond the stated range may cause overvoltage protection
(OVP) to operate, whereby all outputs will turn off. To reset OVP, turn back output
voltage adjustment and remove the mains supply fpr 30 seconds.
Unit Limitations
Output Parameters
Servicing
These products are not customer serviceable. Repairs may only be carried out by TDK-Lambda
Limited or their authorised agents. These products are not authorised for use as critical components in
nuclear control systems, life support systems or equipment for use in hazardous environments without
the express written approval of the Managing Director of TDK-Lambda Limited.
Energy Hazards and SELV
Certain modules are capable of providing hazardous energy (240VA) according to output voltage set-
ting. Final equipment manufacturers must provide protection to service personnel against inadvertent
contact with these module output terminals. If set such that hazardous energy can occur then the
module terminals or connections must not be user accessible.
Approval Limitations: Use in North America (AC units only)
When this product is used on 180VAC-250VAC mains with no neutral, connect the two live wires to
L(live) and N (neutral) terminals on the input connector. In this instance double pole fusing is required.
High Voltage Warning
Dangerous voltages present within the power supply. Do not remove covers.
External Hot Surfaces
Section 6 of the Health and Safety at Work Act requires that manufacturers have an obligation to
protect service engineers as well as users. In order to comply with this, a label must be fi tted to these
products which is clearly visible to service personnel accessing the overall equipment, and which
legibly warns that surfaces of these products may be hot and must not be touched when the products
are in operation
Safety Earthing Screw
On products with an enclosure, special safety earthing screws are used which connect the cover to
the chassis. They must not be removed.
Safety Class of Protection
These products are designed for the following parameters : Material Group IIIb, Pollution Degree 2,
Overvoltage Category II, Class 1 (earthed), Indoor use as part of an overall equipment such that
the product is accessible to service engineers only.
Important safety Instructions
Modules Note Output Range
(*11)
Current Slots Turns Max Current
Limit
Settings for
hazardous
energy
A 4.5-5.5V 60A 2 1 79.2A >3V
AA 4.5-6.2V 60A 2 1 79.2A >3V
AL 4.95-5.05V 60A 2 1 79.2A .>3V
B 1 4.5-5.5V 25A 1 1 33A -
BB 1 4.5-6.5V 25A 1 1 33A -
C 4,6,9 5-16V 16A 1 2 21.2A >11.3V
CM 4,9 5.2-6.6V 16A 1 2 21.2A -
CL 4,9 4.75-5.3V 16A 1 2 21.2A -
CH 4,6,9 11.9-12.7V 16A 1 2 21.2A >11.3V
D 2,9 18-29V 8A 1 4 10-6A >22.6V
E 2 5-16V 8A 1 2 10.6A -
5-16V 8A 2 10.6A -
EB 4.5-5.5V 9A 1 1 11.9V -
4.5-5.5V 9A 1 11.9V -
EH 11.9-12.7V 8A 1 2 10.6A -
11.9-12.7V 8A 2 10.6A -
EL 5.2-6.6V 8A 1 2 10.6A -
11.9-12.7V 8A 2 10.6A -
EQ 4.5-5.5V 9A 1 1 11.9A -
2.7-3.9V 9A 1 11.9A -
F 9 9-16V 33A 2 2 43.6A >5.5V
FF 10-13V 33.5A 2 2 34.5A >6.9V
G 3,9 17.5-29V 25A 2 4 33A >7.2V
H 8 18-32V 5A 1 4 6.6A -
18-32V 5A 4 6.6A -
J 7,9,10 30-48V 10A 2 4(16) 13A >18.4
K 9 18-29V 15A 2 4 19.8A >12V
L 1,9 1.8-3.2V 25A 1 1 33A -
M 9 5-16V 8A 1 2 10.6A -
N 8,9 18-32V 5A 1 4 6.6V -
Modules Note Output Range Current Slots Turns Max current limit Settings for
hazardous
energy
P 18-29V 5A 1 4 6.6A -
5-16V 8A 2 10.6A -
PL 23.6-24.5V 5A 1 4 6.6A -
4.75-5.3V 8A 2 10.6A -
Q 1,9 2.7-3.9V 25A 1 1 33A -
R 9 2.7-3.9V 60A 2 1 79.2A >3V
S 5,9 2.5-5.7V 85A 2 1 110.5A >2.2V
T 9 1.8-3.2V 60A 2 1 79.2A >3V
U 9 10-21V 16A 1 3 21.2A >11.3
W 4.5-5.5V 15A 1 1 19.8A -
Z 1 4.5-5.5V 25A 1 1 33A -
Input Voltage
Intermittent Output
Power Rating
Continuous Output
Power Rating
Maximum Ambient
Temperature
90 - 100VAC - 1000W 45DegC
100 - 264VAC - 1000W 50DegC
85 - 264VAC - 800W 50DegC
120 - 360VDC - 800W 45DegC
85 - 90VAC 1000W * - 50DegC
* - 1000W for 30 seconds maximum followed by 800W for 60 seconds minimum.