Strany 1 - Node Power Supply

Node Power SupplyNode Power Supply EnclosuresInstallation ManualEffective: April 2009Alpha Technologies

Strany 2 - Alpha Technologies

10031-295-B0-001 Rev. A1.0 Introduction1.1 Node Power Supply (NPS) EnclosuresThe NPS enclosures are equipped with AC service entrances, AC distributi

Strany 3 - Installation Manual

11031-295-B0-001 Rev.A1.0 IntroductionSpecifi cationsMaterial: Exterior powder-coated aluminumVent Screen: Stainless mesh (required for outdoor applic

Strany 4 - Table of Contents

12031-295-B0-001 Rev. A1.0 Introduction1.3 Parts ListEnclosure ComponentsDescription Part NumberEnclosure Assembly, NPS 031-295-20Installation Compone

Strany 5 - Figures & Tables

13031-295-B0-001 Rev.A2.0 InstallationFig. 2-1, Dimensions, pole-mounted NPS Enclosure16.25"SPIUpper mounting strapEnclosure ground pointLower mo

Strany 6 - Safety Notes

14031-295-B0-001 Rev. A2.0 Installation2.1 Pole-mounted version, continued 2.1.2 Installation on Wooden PoleNever transport the unit with batteries

Strany 7 - Mechanical Safety

Fig. 2-2, Wooden Pole InstallationUpper mounting bracketService entranceEnclosure ground fi ttingLower Mounting bracket#8 AWG (minimum) Copper Ground W

Strany 8 - Chemical Hazards

16031-295-B0-001 Rev. A2.0 Installation2.1 Pole-mounted version, continued 2.1.3 Installation on Steel/Concrete Pole Never transport the unit with b

Strany 9 - Grounding Connection Notes

17031-295-B0-001 Rev.A2.0 InstallationFig. 2-3, Steel/Concrete Pole Installation2.1 Pole-mounted version, coninued 2.1.3 Installation on Steel/Concr

Strany 10 - 1.0 Introduction

18031-295-B0-001 Rev. A2.0 Installation2.1 Pole-mounted version, continued 2.1.4 Populating the Cabinet and Turn-up1. Make the necessary utility con

Strany 11

19031-295-B0-001 Rev.A2.0 Installation2.2 Rack-mounted version2.2.1 Dimensions and features24.85"1.0"1.0"Fig. 2-4, Dimensions, Rack-mo

Strany 12 - 1.3 Parts List

PowerAlpha Technologies®

Strany 13 - 2.1 Pole-mounted version

20031-295-B0-001 Rev. A2.0 Installation2.2 Rack-mounted version, continued 2.2.2 Installation ProcedureTools required: 3/8" wrench and socket

Strany 14

21031-295-B0-001 Rev.A2.0 Installation2.3 Wall-mounted version2.3.1 Dimensions and features16.00"5.00"17.75"3.20"17.00"4.0&q

Strany 15

22031-295-B0-001 Rev. A2.0 Installation2.3 Wall-mounted version, continued 2.3.2 Installation Verify the following are on hand before installation:

Strany 16

23031-295-B0-001 Rev.A2.0 Installation2.4 Floor-mounted version2.4.1 Dimensions and featuresFig. 2-6, Dimensions, Floor-mounted NPS Enclosure4.0"

Strany 17

24031-295-B0-001 Rev. A2.0 Installation2.4 Floor-mounted version, continued2.4.2 InstallationTools required for floor-mounting configuration: Masonry

Strany 18

ONLY qualifi ed personal should connect the utility power. Power must be connected in compliance with local electrical codes, and common safety practic

Strany 19 - 2.2 Rack-mounted version

26031-295-B0-001 Rev. A2.0 Installation2.5 Connecting the Utility Power, continued 2.5.1 Service PowerConnecting to utility power must be performed

Strany 20 - 2.2.2 Installation Procedure

27031-295-B0-001 Rev.A2.0 InstallationL1 (Black)Neutral (White)Ground (Green)Fig. 2-9 520-R Receptacle WiringFig. 2-8, Breaker Quad Option DSE-20 120V

Strany 21 - 16.00"

2.6 Connecting the Coaxial Cable2.6.1 Coaxial Cable Surge Protector Installation InstructionsAlpha recommends using coaxial surge suppression for enc

Strany 22 - 2.3.2 Installation

Disconnect all power sources from the SPI (Service Power Inserter) before removing its cover. Verify that the SPI is disconnected from both the utilit

Strany 23

3031-295-B0-001 Rev.A031-295-B0-001, Rev. AEffective Date: April, 2009Copyright© 2009Alpha Technologies, Inc. Node Power Supply EnclosuresInstallation

Strany 24 - 2.4.2 Installation

Installation Procedure:1. Use the hammer and punch to remove the 3/4" knockout from either the right side (as viewed from the front) or the r

Strany 25 - WARNING!

31031-295-B0-001 Rev.A2.0 Installation2.7 Battery InstallationThe following precautions must be observed when maintaining batteries:• Remove all pers

Strany 26 - From Utility

2.7 Battery Installation, continued2.7.1 Battery Installation Procedure Procedure:1. Place the batteries on the enclosure’s battery slide tray or b

Strany 27

2.7 Battery Installation, continued2.7.2 Battery Wiring DiagramFig. 2-16, NPS Battery Wiring Diagram with 85GXL battery stringTemperature Probe(Conn

Strany 28

Various types of batteries with different mounting styles and hardware may be shipped with the system. ALWAYS refer to the battery manufacturer’s spec

Strany 29

4. After verifying that the batteries, battery connections, and battery cables are connected properly, plug the battery cable connector from the batt

Strany 30

36031-295-B0-001 Rev. A2.0 Installation2.10 Cooling Fan Kit RemovalTo remove the fan kit, follow the procedure below:1. Open enclosure door and remo

Strany 32

Due to continuing product improvements, Alpha reserves the right to change specifi cations without notice. Copyright © 2009 Alpha Technologies, Inc. Al

Strany 33 - 2.7.2 Battery Wiring Diagram

4031-295-B0-001 Rev. ASafety Information ...

Strany 34

5031-295-B0-001 Rev.AFigures & TablesFig. 1-1 NPS Enclosures ...

Strany 35

6031-295-B0-001 Rev. ASafety NotesReview the drawings and illustrations contained in this manual before proceeding. If there are any questions regardi

Strany 36 - 2.10 Cooling Fan Kit Removal

7031-295-B0-001 Rev.ABattery Maintenance GuidelinesThe battery maintenance instructions listed below are for reference only. Battery manufacturer’s in

Strany 37

8031-295-B0-001 Rev. ABattery Safety NotesChemical HazardsAny gelled or liquid emissions from a valve-regulated lead-acid (VRLA) battery contain dilut

Strany 38

9031-295-B0-001 Rev.A1.0 IntroductionGrounding Connection NotesIn order to provide a ready, reliable source of backup power it is necessary to connect